PRTG Manual: SNMP UPS Status Sensor
The SNMP UPS Status sensor monitors the status of an uninterruptible power supply (UPS) via Simple Network Management Protocol (SNMP).
This sensor is in beta status. The operating methods and the available settings are still subject to change. Do not expect that all functions work properly, or that this sensor works as expected at all.
For a detailed list and descriptions of the channels that this sensor can show, see section Channel List.
- Dutch: SNMP UPS Status
- French: SNMP UPS Status
- German: SNMP USV-Zustand
- Japanese: SNMP UPS Status
- Portuguese: SNMP UPS Status
- Russian: SNMP UPS Status
- Simplified Chinese: SNMP UPS Status
- Spanish: SNMP Estado del UPS
Consider the following remarks and requirements for this sensor:
Requirement |
Description |
---|---|
This sensor requires that the Beta Sensors experimental feature is enabled. For more information, see the Knowledge Base: What are beta sensors and how can I use them? |
|
Credentials |
This sensor requires credentials for SNMP in settings that are higher in the object hierarchy. |
SNMP v2c or SNMP v3 |
We recommend that you select SNMP v2c (most common) or SNMP v3 in the credentials for SNMP devices of the parent device (if supported by the target device). SNMP v1 does not support 64-bit counters, which might result in invalid data. For more information, see the Knowledge Base: SNMP Traffic sensor suddenly drops at 610Mbps |
Localhost |
It might not work to query data from a probe device via SNMP (querying localhost, 127.0.0.1, or ::1). Add this device with the IP address that it has in your network and create the sensor on this device instead. |
IPv6 |
This sensor supports IPv6. |
Performance impact |
This sensor has a very low performance impact. |
Lookups |
This sensor uses lookups to determine the status values of one or more channels. |
Scanning interval |
The recommended scanning interval of this sensor is 1 minute. |
Multi-platform probe |
You can add this sensor to a multi-platform probe. |
The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:
- battery
- snmp
- ups
For more information about basic sensor settings, see section Sensor Settings.
Setting |
Description |
---|---|
Primary Channel |
Select a channel from the list to define it as the primary channel. In the device tree, PRTG displays the last value of the primary channel below the sensor's name. The available options depend on what channels are available for this sensor. You can set a different primary channel later by clicking below a channel gauge on the sensor's Overview tab. |
Graph Type |
Define how this sensor shows different channels:
|
Stack Unit |
This setting is only visible if you select Stack channels on top of each other above. Select a unit from the list. PRTG stacks all channels with this unit on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so. |
Setting |
Description |
---|---|
Result Handling |
Define what PRTG does with the sensor result:
This option is not available when the sensor runs on the hosted probe of a PRTG Hosted Monitor instance. In a cluster, PRTG stores the result in the PRTG data directory of the master node. |
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click under the corresponding setting name to disable the inheritance and to display its options.
For more information, see section Inheritance of Settings.
Which channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.
Channel |
Description |
---|---|
Battery Status |
The battery status
This channel is the primary channel by default. |
Charge Remaining |
The remaining charge (%) This channel has default limits:
|
Current Load |
The current load (%) |
Downtime |
In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status. |
Estimated Time Remaining |
The estimated remaining time until the UPS reaches 0% |
KNOWLEDGE BASE
What are beta sensors and how can I use them?
What security features does PRTG include?