PRTG Manual: SNMP Cisco UCS System Health Sensor
The SNMP Cisco UCS System Health sensor monitors the system health of a Cisco Unified Computing System (UCS) device via the Simple Network Management Protocol (SNMP).
For a detailed list and descriptions of the channels that this sensor can show, see section Channel List.
- Dutch: SNMP Cisco UCS Systeemstatus
- French: Cisco UCS état du système (SNMP)
- German: SNMP Cisco UCS Systemzustand
- Japanese: SNMP Cisco UCS システムの正常性
- Portuguese: Saúde do sistema Cisco UCS (SNMP)
- Russian: Работоспособность системы SNMP Cisco UCS
- Simplified Chinese: SNMP Cisco UCS 系统健康状况
- Spanish: Salud de sistema Cisco UCS (SNMP)
Consider the following remarks and requirements for this sensor:
Remark |
Description |
---|---|
IPv6 |
This sensor supports IPv6. |
Performance impact |
This sensor has a medium performance impact. |
Lookups |
This sensor uses lookups to determine the status values of one or more channels. |
The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:
- snmpciscosystemhealthsensor
- systemhealth
- ucs
- ucssystemhealth
For more information about basic sensor settings, see section Sensor Settings.
Setting |
Description |
---|---|
Primary Channel |
Select a channel from the list to define it as the primary channel. In the device tree, PRTG displays the last value of the primary channel below the sensor's name. The available options depend on what channels are available for this sensor. You can set a different primary channel later by clicking below a channel gauge on the sensor's Overview tab. |
Graph Type |
Define how this sensor shows different channels:
|
Stack Unit |
This setting is only visible if you select Stack channels on top of each other above. Select a unit from the list. PRTG stacks all channels with this unit on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so. |
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click under the corresponding setting name to disable the inheritance and to display its options.
For more information, see section Inheritance of Settings.
Which channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.
Channel |
Description |
---|---|
Critical Faults Count |
The number of critical faults (that are not yet acknowledged in the UCS logs) This channel has a default limit:
|
Downtime |
In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status. |
Fan Failure Predicted |
The predicted fan failure status
|
Fan Module Failure Predicted |
The predicted fan module failure status
|
Fan Module Performance |
The fan module performance status
|
Fan Module Thermal |
The fan module thermal status
|
Fan Modules Inoperable |
The number of operable fan modules This channel has a default limit:
|
Fan Modules Operable |
The number of inoperable fan modules |
Fan Performance |
The fan performance
|
Fan Thermal |
The fan thermal status
|
Fans Inoperable |
The number of inoperable fan modules This channel has a default limit:
|
Fans Operable |
The number of operable fan modules This channel is the primary channel by default. |
Major Faults Count |
The number of major faults (that are not yet acknowledged in the UCS logs) This channel has a default limit:
|
Minor Faults Count |
The number of minor faults (that are not yet acknowledged in the UCS logs) This channel has a default limit:
|
Power Supplies Inoperable |
The number of inoperable power supplies This channel has a default limit:
|
Power Supplies Operable |
The number of operable power supplies |
Power Supply Failure Predicted |
The predicted power supply failure status
|
Power Supply Performance |
The power supply performance status
|
Power Supply Thermal |
The power supply thermal status
|
Power Supply Voltage |
The power supply voltage status
|
Warning Count |
The number of warnings (that are not yet acknowledged in the UCS logs) This channel has a default limit:
|
KNOWLEDGE BASE
What security features does PRTG include?
My SNMP sensors don’t work. What can I do?