PRTG Manual: jFlow v5 Sensor
The jFlow v5 sensor receives traffic data from a jFlow v5-compatible device and shows the traffic by type. This sensor has several filter options to divide traffic into different channels.
Make sure that the sensor matches the jFlow version that your device exports.
For a detailed list and descriptions of the channels that this sensor can show, see section Channel List.
- Dutch: jFlow v5
- French: jFlow v5
- German: jFlow v5
- Japanese: jFlow v5
- Portuguese: jFlow v5
- Russian: jFlow v5
- Simplified Chinese: jFlow v5
- Spanish: jFlow v5
Consider the following remarks and requirements for this sensor:
Remark |
Description |
---|---|
Performance impact |
This sensor has a very high performance impact. We recommend that you use no more than 50 of this sensor on each probe. |
jFlow |
This sensor requires that the jFlow export of the respective version is enabled on the target system. The target system must send the flow data stream to the IP address of the probe system. |
Cluster probe |
This sensor does not support cluster probes. You can only set it up on local probes or remote probes. |
IPv4 |
This sensor only supports IPv4. |
Clone sensor |
If you clone this sensor to the same probe, PRTG keeps the selected IP addresses on which it listens for Flow (NetFlow, jFlow, sFlow, IPFIX) packets. If you clone this sensor to a different probe, PRTG selects all available IP addresses by default. |
Knowledge Base |
|
Hosted probe |
You cannot add this sensor to the hosted probe of a PRTG Hosted Monitor instance. If you want to use this sensor, add it to a remote probe device. |
The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:
- bandwidthsensor
- jflowsensor
For more information about basic sensor settings, see section Sensor Settings.
Setting |
Description |
---|---|
Receive Packets on UDP Port |
Enter the UDP port number on which PRTG receives the flow packets. It must match the UDP port number that in the jFlow export options of the hardware router device. Enter an integer. When you configure the export, make sure that you select the appropriate jFlow version for this sensor. |
Sender IP Address |
Enter the IP address of the sending device that you want to receive the jFlow data from. Enter an IP address to only receive data from a specific device or leave the field empty to receive data from any device on the specified port. |
Select the IP addresses on which PRTG listens to jFlow packets. The list of IP addresses is specific to your setup. To select an IP address, enable a check box in front of the respective line. The IP address that you select must match the IP address in the jFlow export options of the hardware router device. When you configure the export, make sure that you select the appropriate jFlow version for this sensor. |
|
Active Flow Timeout (Minutes) |
Enter a time span in minutes after which the sensor must receive new flow data. If the timeout elapses and the sensor receives no new data during this time, it shows the Unknown status. Enter an integer. The maximum timeout is 60 minutes. We recommend that you set the timeout one minute longer than the timeout in the hardware router device. If you set this value too low, flow information might be lost. For more information, see the Knowledge Base: What is the Active Flow Timeout in flow sensors? |
Sampling Mode |
Define if you want to use the sampling mode:
This setting must match the setting in the xFlow exporter. |
Sampling Rate |
This setting is only visible if you select Enable above. Enter a number that matches the sampling rate in the exporting device. If the number is different, monitoring results will be incorrect. Enter an integer. |
Stream Data Handling |
Define what PRTG does with the stream and packet data:
Use with caution. It can create huge data files. We recommend that you only use this setting for a short time. |
Setting |
Description |
---|---|
Channel Selection |
Define the categories that the sensor accounts the traffic to:
For each group, you can select how many channels the sensor uses, that is, how detailed the sensor divides the traffic:
You can change the default configuration for groups and channels. For more information, see the Knowledge Base: How can I change the default groups and channels for flow and Packet Sniffer sensors? |
For more information, see section Filter Rules.
Setting |
Description |
---|---|
Include Filter |
Define if you want to filter any traffic. If you leave this field empty, the sensor includes all traffic. To include specific traffic only, define filters using a special syntax. |
Exclude Filter |
First, the sensor considers the filters in Include Filter. From this subset, you can explicitly exclude traffic, using the same syntax. |
Setting |
Description |
---|---|
Primary Channel |
Select a channel from the list to define it as the primary channel. In the device tree, PRTG displays the last value of the primary channel below the sensor's name. The available options depend on what channels are available for this sensor. You can set a different primary channel later by clicking below a channel gauge on the sensor's Overview tab. |
Graph Type |
Define how this sensor shows different channels:
|
Stack Unit |
This setting is only visible if you select Stack channels on top of each other above. Select a unit from the list. PRTG stacks all channels with this unit on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so. |
Setting |
Description |
---|---|
Primary Toplist |
Define which Toplist is the primary Toplist of the sensor:
PRTG shows the primary Toplist in maps when you add a Toplist object. |
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click under the corresponding setting name to disable the inheritance and to display its options.
For more information, see section Inheritance of Settings.
For all Flow (NetFlow, jFlow, sFlow, IPFIX) and Packet Sniffer sensors, Toplists are available on the sensor's Overview tab. Using Toplists, you can review traffic data for small time periods in great detail.
For more information, see section Toplists.
The following filter rules apply to all Flow (NetFlow, jFlow, sFlow, IPFIX) and Packet Sniffer sensors.
For more information, see section Filter Rules for Flow, IPFIX, and Packet Sniffer Sensors.
Field |
Possible Filter Values |
---|---|
IP |
IP address or DNS name |
Port |
Any number |
SourceIP |
IP address or DNS name |
SourcePort |
Any number |
DestinationIP |
IP address or DNS name |
DestinationPort |
Any number |
Protocol |
Transmission Control Protocol (TCP), User Datagram Protocol (UDP), Internet Control Message Protocol (ICMP), Open Shortest Path First (OSPF), any number |
ToS |
Type of Service (ToS): any number |
DSCP |
Differentiated Services Code Point (DSCP): any number |
The following filter rules apply to jFlow v5 sensors only.
Field |
Possible Filter Values |
---|---|
Interface |
Any number |
ASI |
Any number |
InboundInterface |
Any number |
OutboundInterface |
Any number |
SenderIP |
IP address of the sending device. Use this if you have several devices that send flow data on the same port, and you want to divide the traffic of each device into a different channel. Possible values: IP address or DNS name |
SourceASI |
Any number |
DestinationASI |
Any number |
Which channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.
Channel |
Description |
---|---|
Chat |
The traffic from chat and instant messaging (IRC, AIM) |
Citrix |
The traffic from Citrix applications |
Downtime |
In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status |
FTP/P2P |
The traffic from file transfer (FTP/P2P) |
Infrastructure |
The traffic from network services (DHCP, DNS, Ident, ICMP, SNMP) |
The internet mail traffic (IMAP, POP3, SMTP) |
|
NetBIOS |
The traffic from NetBIOS communication |
Other |
The traffic from various other protocols (UDP, TCP) |
Remote Control |
The traffic from remote control applications (RDP, SSH, Telnet, Virtual Network Computing (VNC)) |
Total |
The total traffic This channel is the primary channel by default. |
Various |
The traffic from various other sources |
WWW |
The traffic from the web (HTTP, HTTPS) |
KNOWLEDGE BASE
What is the Active Flow Timeout in flow sensors?
How can I change the default groups and channels for flow and Packet Sniffer sensors?
What security features does PRTG include?
Where is the volume line in graphs?