PRTG Manual: SSH SAN Logical Disk Sensor

The SSH SAN Logical Disk sensor monitors a logical disk on a storage area network (SAN) via Secure Shell (SSH).

i_round_redThe SAN must provide a command-line interface (CLI) for this purpose.

SSH SAN Logical Disk Sensor

SSH SAN Logical Disk Sensor

i_square_cyanFor a detailed list and descriptions of the channels that this sensor can show, see section Channel List.

Sensor in Other Languages

  • Dutch: SSH SAN Logische Schijf
  • French: SAN disque logique (SSH)
  • German: SSH SAN Logisches Laufwerk
  • Japanese: SSH SAN 論理ディスク
  • Portuguese: Disco lógico SAN (SSH)
  • Russian: Логический диск SAN по SSH
  • Simplified Chinese: SSH SAN 逻辑磁盘
  • Spanish: Disco lógico SAN (SSH)

Remarks

Consider the following remarks and requirements for this sensor:

Remark

Description

Credentials

This sensor requires credentials for Linux/Solaris/macOS (SSH/WBEM) systems in the settings of the parent device.

SAN support

This sensor does not support every SAN, even if it provides a CLI. This sensor only works with specific devices, for example, the HPE P2000.

Scanning interval

If the controller of the target system breaks down, increase the scanning interval to discharge the controller and try again.

Firmware update

After a firmware update of the target system, this sensor might show incorrect channel values. Add this sensor anew in this case.

Performance impact

This sensor has a medium performance impact.

IPv4

This sensor only supports IPv4.

Lookups

This sensor uses lookups to determine the status values of one or more channels.

Device status

Sometimes the devices you monitor with this sensor return status values that are not officially documented so that the shown sensor status in PRTG differs from the "real" device status. For more information, see the Knowledge Base: Why does my SSH SAN sensor show a wrong status?

Knowledge Base

Knowledge Base: Which encryption algorithms do PRTG SSH sensors support?

Basic Sensor Settings

Basic Sensor Settings

Basic Sensor Settings

The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:

  • logicaldisk
  • sshsan
  • sshsanlogicaldisk

i_square_cyanFor more information about basic sensor settings, see section Sensor Settings.

SSH Specific

SSH Specific

SSH Specific

Setting

Description

Connection Timeout (Sec.)

Define a timeout in seconds for the connection. This is the time that the sensor waits to establish a connection to the host. Keep this value as low as possible. Enter an integer.

i_round_blueThis sensor has a fixed timeout of 300 seconds. If you change the value, it does not have an effect on the timeout.

i_round_blueMake sure that the connection timeout is a value that is higher than the shell timeout to avoid potential errors.

Shell Timeout (Sec.)

Define a timeout in seconds for the shell response. This is the time in seconds the sensor waits for the shell to return a response after it has sent its specific command (for example, cat /proc/loadavg). The maximum value is 300 seconds (5 minutes). Enter an integer.

i_round_blueThis sensor has a fixed timeout of 300 seconds. If you change the value, it does not have an effect on the timeout.

i_round_blueMake sure that the shell timeout is a value that is lower than the connection timeout to avoid potential errors.

SSH Port Inheritance

Define which port this sensor uses for the SSH connection:

  • Inherit port from parent device (default): Use the port number as defined in the Credentials for Linux/Solaris/macOS (SSH/WBEM) Systems section of the parent device settings.
  • Do not inherit port (enter a custom SSH port): Define a custom port number below and do not use the port number from the parent device settings.

Custom SSH Port

This setting is only visible if you select Do not inherit port (enter a custom SSH port) above.

Enter the port number (between 1 and 65535) that this sensor uses for the SSH connection. Enter an integer.

SSH Engine

Select the SSH engine that you want to use to access data with this SSH sensor:

  • Inherit from parent device (default): Use the SSH engine that you defined in the parent device settings or higher up in the object hierarchy. If you have not changed the SSH engine, this is the recommended option.
  • Default: This is the default SSH engine. It provides the best performance and security. It is set by default in objects that are higher up in the hierarchy, so usually you can keep the Inherit from parent device (default) option.
  • Compatibility mode (deprecated): Use this only if the default SSH engine does not work on a target device. The compatibility mode is the SSH engine that PRTG used in previous versions. It is deprecated. We will remove this legacy mode soon, so try to get your SSH sensors to run with the default SSH engine.

i_round_redWe strongly recommend that you use the default SSH engine.

i_round_redThe option you select here overrides the selection of the SSH engine in a higher object: a parent device, group, probe, or root.

Result Handling

Define what PRTG does with the sensor result:

  • Discard result (default): Do not store the sensor result.
  • Store result: Store the sensor result and the last response in the \Logs\sensors subfolder of the PRTG data directory on the probe system. The file names are Result of Sensor [ID].txt, Result of Sensor [ID].Data.txt, and Result of Sensor [ID] (SSHv2).txt. This setting is for debugging purposes. PRTG overwrites these files with each scanning interval.
  • Store result in case of error: Store the last sensor result only if the sensor shows the Down status.

i_podThis option is not available when the sensor runs on the hosted probe of a PRTG Hosted Monitor instance.

i_round_blueIn a cluster, PRTG stores the result in the PRTG data directory of the master node.

SSH SAN Logical Disk Settings

SSH SAN Logical Disk Settings

SSH SAN Logical Disk Settings

Setting

Description

Volume

The volume that this sensor monitors.

Size

The size of the volume that this sensor monitors.

Command Mode

Define the command set that the sensor uses on the device to get monitoring data:

  • Basic (default): Use the basic command set. We recommend that you use the basic command set for best sensor performance. This setting is appropriate for most scenarios.
  • Advanced: Monitor additional data on the target device like IOs and bandwidth.
    i_round_redBecause this setting results in higher usage of system resources and so might cause sensor instabilities, we strongly recommend that you ony select this option if this data is crucial for the volume that you monitor.

Sensor Display

Sensor Display

Sensor Display

Setting

Description

Primary Channel

Select a channel from the list to define it as the primary channel. In the device tree, PRTG displays the last value of the primary channel below the sensor's name. The available options depend on what channels are available for this sensor.

i_round_blueYou can set a different primary channel later by clicking b_channel_primary below a channel gauge on the sensor's Overview tab.

Graph Type

Define how this sensor shows different channels:

  • Show channels independently (default): Show a graph for each channel.
  • Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic.
    i_round_redYou cannot use this option in combination with manual Vertical Axis Scaling (available in the channel settings).

Stack Unit

This setting is only visible if you select Stack channels on top of each other above.

Select a unit from the list. PRTG stacks all channels with this unit on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.

Inherited Settings

By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click b_inherited_enabled under the corresponding setting name to disable the inheritance and to display its options.

i_square_cyanFor more information, see section Inheritance of Settings.

Channel List

i_round_blueWhich channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.

Channel

Description

Downtime

In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status.

Health

The disk heath status

  • Up status: Ok
  • Down status: Fault, Not Available

i_round_blueThis channel is the primary channel by default.

Total IOs

The total number of I/O operations

Transferred

The data transferred

More

i_square_blueKNOWLEDGE BASE

Which encryption algorithms do PRTG SSH sensors support?

Why does my SSH SAN sensor show a wrong status?

What security features does PRTG include?