PRTG Manual: SNMP HPE ProLiant System Health Sensor

The SNMP HPE ProLiant System Health sensor monitors the system health of an HPE ProLiant server via the Simple Network Management Protocol (SNMP).

SNMP HPE ProLiant System Health Sensor

SNMP HPE ProLiant System Health Sensor

i_square_cyanFor a detailed list and descriptions of the channels that this sensor can show, see section Channel List.

Sensor in Other Languages

  • Dutch: SNMP HPE ProLiant Systeemstatus
  • French: HPE ProLiant état du système (SNMP)
  • German: SNMP HPE ProLiant Systemzustand
  • Japanese: SNMP HPE ProLiant システム正常性
  • Portuguese: Saúde do sistema HPE ProLiant (SNMP)
  • Russian: Работоспособность системы HPE ProLiant по SNMP
  • Simplified Chinese: SNMP HPE ProLiant 系统健康状况
  • Spanish: Salud de sistema HPE ProLiant (SNMP)

Remarks

Consider the following remarks and requirements for this sensor:

Remark

Description

HPE system management tools

For Gen10 servers: Use the HPE Integrated Lights Out (iLO) interface as the parent device.

For Gen9 servers or earlier: This sensor requires HPE Insight Management Agents and HPE Insight Management WBEM Providers on the target system.

i_round_blueFor Gen9 servers or earlier, this sensor requires a specific HPE system management tool to be installed on the target system to report data via SNMP: HPE Insight Management Agents. To receive SNMP data from redundant array of independent disks (RAID) controllers, the sensor also requires HPE Insight Management Agents. For Gen10 servers, this sensor no longer requires HPE system management tools.

i_square_cyanFor more information and download links, see the Knowledge Base: Monitor HP ProLiant via SNMP?

i_round_blueFor Gen9 servers or earlier, some of the HPE object identifiers (OID) that this sensor uses are only accessible via the iLO interface. If this sensor throws an error that it cannot find "such device types", create a device that points to the address of the HPE iLO interface (if available) and add the sensor to this device. We recommend that you use the Agentless Management feature with configured SNMP. You can set this up in the iLO configuration interface under Administration | Management | SNMP Settings. For Gen10 servers, use the HPE iLO interface as parent device for this sensor.

iLO versions

This sensor supports iLO as of iLO 3. We recommend that you use at least iLO 4.

IPv6

This sensor supports IPv6.

Performance impact

This sensor has a low performance impact.

Lookups

This sensor uses lookups to determine the status values of one or more channels.

Limits

This sensor has predefined limits for temperatures and broken frames.

RAID controllers

Redundant array of independent disks (RAID) controllers that have no hard disks assigned might cause the Down status. In this case, deactivate the respective controllers in the HPE ProLiant BIOS to avoid sensor errors.

Basic Sensor Settings

Basic Sensor Settings

Basic Sensor Settings

The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:

  • hpe
  • snmphpe
  • snmphpesystemhealthsensor
  • systemhealth

i_square_cyanFor more information about basic sensor settings, see section Sensor Settings.

Sensor Display

Sensor Display

Sensor Display

Setting

Description

Primary Channel

Select a channel from the list to define it as the primary channel. In the device tree, PRTG displays the last value of the primary channel below the sensor's name. The available options depend on what channels are available for this sensor.

i_round_blueYou can set a different primary channel later by clicking b_channel_primary below a channel gauge on the sensor's Overview tab.

Graph Type

Define how this sensor shows different channels:

  • Show channels independently (default): Show a graph for each channel.
  • Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic.
    i_round_redYou cannot use this option in combination with manual Vertical Axis Scaling (available in the channel settings).

Stack Unit

This setting is only visible if you select Stack channels on top of each other above.

Select a unit from the list. PRTG stacks all channels with this unit on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.

Inherited Settings

By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click b_inherited_enabled under the corresponding setting name to disable the inheritance and to display its options.

i_square_cyanFor more information, see section Inheritance of Settings.

Channel List

i_round_blueWhich channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.

Channel

Description

CPU Fan Status

The CPU fan status

  • Up status: OK
  • Warning status: Degraded
  • Down status: Failed
  • Unknown status: Other

Disk Controller Status

The disk controller status

  • Up status: OK
  • Warning status: Degraded
  • Down status: Failed
  • Unknown status: Other

Downtime

In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status

Fans Broken

The number of broken fans

i_round_blueThis channel has a default limit:

  • Upper error limit: 0

Fans Running

The number of running fans

Fault Tolerant Fans Broken

The number of fault-tolerant broken fans

i_round_blueThis channel has a default limit:

  • Upper error limit: 0

Fault Tolerant Fans Running

The number of fault-tolerant running fans

Overall Status

The overall status

  • Up status: OK
  • Warning status: Degraded
  • Down status: Failed
  • Unknown status: Other

i_round_blueThis channel is the primary channel by default.

Power Consumption [#]

The power consumption

Power Consumption [#] (%)

The power consumption (%)

Power Supply [#] Condition

The power supply condition

  • Up status: OK
  • Down status: Degraded, Failed
  • Unknown status: Other

Power Supply [#] Status

The power supply status

  • Up status: No Error
  • Down status: Bist Failure, Brownout, Calibration Table Invalid, Dac Failure, Eprom Failure, Fan Failure, General Failure, Give Up On Startup, Interlock Open, No Power Input, Nvram Invalid, Orring Diode Failed, Ram Test Failed, Temp Failure, Voltage Channel Failed, Vref Failure

System Fan Status

The system fan status

  • Up status: OK
  • Warning status: Degraded
  • Down status: Failed
  • Unknown status: Other

Temperature [#] ([Component])

The temperature of the component

Thermal Status

The thermal status

  • Up status: OK
  • Warning status: Degraded
  • Down status: Failed
  • Unknown status: Other

More

i_square_blueKNOWLEDGE BASE

Monitor HP ProLiant via SNMP?

What security features does PRTG include?

Why is my SNMP HPE ProLiant System Health sensor in the error status after updating PRTG?

My SNMP sensors don’t work. What can I do?