PRTG Manual: RDP (Remote Desktop) Sensor
The RDP (Remote Desktop) sensor monitors remote desktop services such as Remote Desktop Protocol (RDP) or Terminal Services Client.
For a detailed list and descriptions of the channels that this sensor can show, see section Channel List.
- Dutch: RDP (Remote Desktop)
- French: RDP (Bureau à distance)
- German: RDP (Remotedesktop)
- Japanese: RDP(リモートデスクトップ)
- Portuguese: RDP (desktop remoto)
- Russian: RDP (удаленный рабочий стол)
- Simplified Chinese: RDP (远程桌面)
- Spanish: RDP (escritorio remoto)
Consider the following remarks and requirements for this sensor:
Remark |
Description |
---|---|
IPv6 |
This sensor supports IPv6. |
Performance impact |
This sensor has a low performance impact. |
The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:
- rdpsensor
For more information about basic sensor settings, see section Sensor Settings.
Setting |
Description |
---|---|
Timeout (Sec.) |
Enter a timeout in seconds for the request. Enter an integer. The maximum timeout value is 900 seconds (15 minutes). If the reply takes longer than this value, the sensor cancels the request and shows a corresponding error message. |
Port |
Enter the number of the port to which this sensor connects. Enter an integer. The default value is 3389. We recommend that you use the default value. |
Setting |
Description |
---|---|
Primary Channel |
Select a channel from the list to define it as the primary channel. In the device tree, PRTG displays the last value of the primary channel below the sensor's name. The available options depend on what channels are available for this sensor. You can set a different primary channel later by clicking below a channel gauge on the sensor's Overview tab. |
Graph Type |
Define how this sensor shows different channels:
|
Stack Unit |
This setting is only visible if you select Stack channels on top of each other above. Select a unit from the list. PRTG stacks all channels with this unit on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so. |
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click under the corresponding setting name to disable the inheritance and to display its options.
For more information, see section Inheritance of Settings.
Which channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.
Channel |
Description |
---|---|
Downtime |
In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status |
Response Time |
The response time This channel is the primary channel by default. |
KNOWLEDGE BASE
What security features does PRTG include?
Does PRTG impair my Citrix environment?