The NetApp Volume v2 sensor monitors a volume of a NetApp storage system via the Representational State Transfer (REST) application programming interface (API) using ONTAP as of version 9.6.

i_round_redThis sensor was converted to a new framework so that it will continue to function after the changes of the ONTAP REST API.

NetApp Volume Sensor

NetApp Volume Sensor

i_square_cyanFor a detailed list and descriptions of the channels that this sensor can show, see section Channel List.

Sensor in Other Languages

  • Dutch: NetApp Volume v2
  • French: NetApp volume de stockage v2
  • German: NetApp Volume v2
  • Japanese: NetApp ボリューム v2
  • Portuguese: Volume NetApp v2
  • Russian: Том NetApp v2
  • Simplified Chinese: NetApp 卷 v2
  • Spanish: Volumen NetApp v2

Remarks

Consider the following remarks and requirements for this sensor:

Remark

Description

Credentials for NetApp

This sensor requires an ONTAP System Manager user account with the role readonly and with access to the HTTP application with Password authentication.

Permissions for the ONTAP REST API

This sensor requires permissions for the ONTAP REST API.

i_round_blueThis sensor requires the role readonly with the following permissions for the ONTAP REST API:

Access level Read-Only:

    • /api
    • /api/security/audit/destinations

Access level Read/Write:

    • /api/security/authentication/password

Access level None:

    • /api/security

Credentials

This sensor requires credentials for NetApp.

NetApp versions

This sensor supports ONTAP as of version 9.6. If you want to use NetApp cDOT as of version 8.3 or ONTAP from version 9.0 to version 9.5, use the NetApp Volume sensor.

IPv6

This sensor supports IPv6.

Performance impact

This sensor has a very low performance impact.

Lookups

This sensor uses lookups to determine the status values of one or more channels.

Limits

This sensor has predefined limits for several metrics.

Scanning interval

  • The minimum scanning interval of this sensor is 1 minute.
  • The recommended scanning interval of this sensor is 1 minute.

Multi-platform probe

You can add this sensor to a multi-platform probe.

Basic Sensor Settings

Basic Sensor Settings

Basic Sensor Settings

The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:

  • netapp
  • ontap
  • rest

i_square_cyanFor more information about basic sensor settings, see section Sensor Settings.

NetApp Specific

NetApp Specific

NetApp Specific

Setting

Description

Volume Name

The name of the volume that this sensor monitors.

Aggregate Names

The names of the aggregates that contain the volume that this sensor monitors.

Sensor Display

Sensor Display

Sensor Display

Setting

Description

Primary Channel

Select a channel from the list to define it as the primary channel. In the device tree, PRTG displays the last value of the primary channel below the sensor's name. The available options depend on what channels are available for this sensor.

i_round_blueYou can set a different primary channel later by clicking b_channel_primary below a channel gauge on the sensor's Overview tab.

Graph Type

Define how this sensor shows different channels:

  • Show channels independently (default): Show a graph for each channel.
  • Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic.
    i_round_redYou cannot use this option in combination with manual Vertical Axis Scaling (available in the channel settings).

Stack Unit

This setting is only visible if you select Stack channels on top of each other above.

Select a unit from the list. PRTG stacks all channels with this unit on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.

Debug Options

Debug Options

Debug Options

Setting

Description

Result Handling

Define what PRTG does with the sensor result:

  • Discard result (default): Do not store the sensor result.
  • Store result: Store the last sensor result in the \Logs\sensors subfolder of the PRTG data directory on the probe system. The file name is Result of Sensor [ID].log. This setting is for debugging purposes. PRTG overwrites this file with each scanning interval.

i_podThis option is not available when the sensor runs on the hosted probe of a PRTG Hosted Monitor instance.

i_round_blueIn a cluster, PRTG stores the result in the PRTG data directory of the master node.

Inherited Settings

By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click b_inherited_enabled under the corresponding setting name to disable the inheritance and to display its options.

i_square_cyanFor more information, see section Inheritance of Settings.

Channel List

i_round_blueWhich channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.

Channel

Description

Autogrow

The autogrow status

  • Up status: Can Grow, Off
  • Warning status: Grow Limit Reached
  • Unknown status: Channel Value Not Set

Downtime

In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status

Files Free

The number of files that can be created on the volume

Files Free %

The number of files that can be created on the volume

i_round_blueThis channel has default limits:

  • Lower error limit: 10%
  • Lower warning limit: 25%

Latest Snapshot

The time since the latest snapshot

Oldest Snapshot

The oldest snapshot age

Physical Bytes Free %

The free physical bytes

i_round_blueThis channel has default limits:

  • Lower error limit: 10%
  • Lower warning limit: 25%

Size Free

The free size

i_round_blueThis channel also takes the snapshot reserve space (if set in the ONTAP System Manager) on the volume into account.

Size Free %

The free size (%)

i_round_blueThis channel is the primary channel by default.

i_round_blueThis channel has default limits:

  • Lower error limit: 10%
  • Lower warning limit: 25%

i_round_blueThis channel also takes the snapshot reserve space (if set in the ONTAP System Manager) on the volume into account.

Snapshot

The number of snapshots

i_round_blueThis channel has a default limit:

  • Upper error limit: 1024

i_round_blueVolumes can contain up to 1023 snapshot copies. The limit of this channel is set to define a fixed size of the gauge that reflects the maximum number of snapshot copies that the volume can contain.