The WMI Terminal Services (Windows 2008+) sensor monitors the number of sessions on a Windows Terminal Services (Remote Desktop Services) server via Windows Management Instrumentation (WMI).
The sensor supports Windows 2008 R2 and later.
For a detailed list and descriptions of the channels that this sensor can show, see section Channel List.
- Dutch: WMI Terminal Services (Windows 2008+)
- French: Windows (2008+) Terminal Services (WMI)
- German: WMI Terminaldienste (Windows 2008+)
- Japanese: WMI ターミナルサービス(Windows 2008 以降)
- Portuguese: Serviços de terminal (Windows 2008+) (WMI)
- Russian: WMI служб терминалов (Windows 2008 и последующая)
- Simplified Chinese: WMI 终端服务 (Windows 2008+)
- Spanish: Terminal Services (Windows 2008+) (WMI)
Consider the following remarks and requirements for this sensor:
Remark |
Description |
---|---|
Performance impact |
This sensor has a high performance impact. Stay below 200 WMI sensors per probe. Above this number, consider using multiple remote probes for load balancing. |
WoW64 |
This sensor requires WoW64 (Windows 32-bit on Windows 64-bit) for target systems that run Windows Server 2016. |
Credentials |
This sensor requires credentials for Windows systems. |
IPv6 |
This sensor supports IPv6. |
Hosted probe |
You cannot add this sensor to the hosted probe of a PRTG Hosted Monitor instance. If you want to use this sensor, add it to a remote probe device. |
The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:
- wmiterminalservicessensor
For more information about basic sensor settings, see section Sensor Settings.
Setting |
Description |
---|---|
Result Handling |
Define what PRTG does with the sensor result:
In a cluster, PRTG stores the result in the PRTG data directory of the master node. |
Setting |
Description |
---|---|
Primary Channel |
Select a channel from the list to define it as the primary channel. In the device tree, PRTG displays the last value of the primary channel below the sensor's name. The available options depend on what channels are available for this sensor. You can set a different primary channel later by clicking below a channel gauge on the sensor's Overview tab. |
Graph Type |
Define how this sensor shows different channels:
|
Stack Unit |
This setting is only visible if you select Stack channels on top of each other above. Select a unit from the list. PRTG stacks all channels with this unit on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so. |
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click under the corresponding setting name to disable the inheritance and to display its options.
For more information, see section Inheritance of Settings.
Which channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.
Channel |
Description |
---|---|
Active Sessions |
The number of active sessions: sessions with a logged in user, including used published applications |
Downtime |
In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status |
Total Sessions |
The total number of sessions (including inactive sessions): inactive sessions can be sessions with a disconnected user that has not logged out or system services using a session For the Total Sessions channel, the sensor returns the number of active and inactive sessions, plus two additional sessions: one for the console, and one for the services. So, the number of total sessions might actually be higher than expected. This channel is the primary channel by default. |